Skip to main content

Olezarsen Targets RNA. How Do You Show an Antisense Candidate Forms the Duplex You Expect?

If two antisense candidates bind the same stretch of RNA and both pairs melt near 70 °C, would you advance them both? In a study by Rouven Stulz and colleagues, one candidate let go of the RNA faster in every run at 37 °C. You’d miss that difference if the melting temperature were the only number in your spreadsheet.

If two antisense candidates bind the same stretch of RNA and both pairs melt near 70 °C, would you advance them both? In a study by Rouven Stulz and colleagues, one candidate let go of the RNA faster in every run at 37 °C. You’d miss that difference if the melting temperature were the only number in your spreadsheet.

On November 17, 2026, Ionis announced an expanded EU indication for olezarsen, marketed as Tryngolza. The EU now authorizes its use alongside diet and other lipid-lowering therapies for adults with severe hypertriglyceridemia whose fasting triglycerides reach at least 880 mg/dL (10 mmol/L). Olezarsen works by pairing with APOC3 messenger RNA in liver cells. That gives an enzyme called RNase H1 a site to cut the RNA, reducing production of the apoC-III protein.

In my earlier post on RNA formulation, I looked at what happens when you change the buffer. Here I want to keep the RNA target fixed and change the chemistry of the antisense oligonucleotide (ASO). How would I tell whether that change helped?

Start with the strands before you mix them

Stulz and colleagues worked with a different target from olezarsen, a 24-nucleotide stretch of PCSK9 RNA. Using an Applied Photophysics Chirascan V100, they collected circular dichroism (CD) spectra for the RNA alone, each candidate alone, and the mixtures. CD measures how differently a sample absorbs left- and right-circularly polarized light. In nucleic acids, it’s sensitive to how the bases stack.

The individual strands turned out to matter. Two candidates already had a peak near 280 nm before they saw any RNA. A third had a peak near 270 nm. Adding the target changed the spectra of all three, while a nonbinding control showed no comparable change.

That’s why I’d build the individual strands into the first run. Without them, it’s easy to credit pairing for a feature the candidate already had. CD gives an overall picture of how the strands are arranged. Pinpointing individual base pairs takes higher-resolution evidence.

A 2026 study of fluorinated antisense candidates targeting C9ORF72 repeat RNA makes the case for measuring the whole spectrum. Barber and colleagues used a Chirascan VX. Two candidate duplexes looked much alike at 265 nm. Near 210 nm, their signals differed, and the authors concluded that one duplex more closely resembled the A-form helix typical of double-stranded RNA. If I’d chosen 265 nm as my only readout, I’d have called those samples much more similar than they were.

Follow the duplex through the melt

Back in the PCSK9 study, Stulz and colleagues used a temperature-controlled Chirascan V100 to record a full spectrum at every degree from 40 to 90 °C. That’s why I’d want this setup for an antisense screen. I can see which peaks distinguish the paired sample at the start, then follow those same peaks in the same cuvette as the strands separate. The melting temperature (Tₘ) gives me the midpoint. The spectra show me what changed on the way there.

That 210 nm example is also where I’d use the V100’s option to record absorbance alongside CD. If the distinction I care about is at the short-wavelength end, I want to know whether enough light reached the detector there. The absorbance trace helps me decide whether a shorter-path cuvette would give me a cleaner comparison.

In Figure 2B, two candidates had CD melting midpoints near 70 °C. ASO 1 had a central stretch of DNA flanked by modified nucleotides, a design called a gapmer. ASO 3 had a 2′-O-methyl modification throughout. To tell how long each stayed paired at 37 °C, the team had to hold the temperature steady and measure release.

What was still bound after 17 minutes?

For the PCSK9 experiment, the team used surface plasmon resonance (SPR). They attached the RNA to a sensor, introduced each candidate, then switched to buffer and watched the signal fall as bound strands came off.

Candidate CD melting midpoint Estimated fraction still bound after 17 min at 37 °C
ASO 1, gapmer About 70 °C 72–85%
ASO 3, fully 2′-O-methyl About 70 °C 44–70%

I calculated those ranges from the three fitted dissociation rates for each candidate in supplementary Table S7, using the authors’ one-to-one binding model over their 17-minute observation window. The gapmer stayed paired longer in all three runs. That’s a useful distinction if time on target is what you’re trying to change.

What would I run on Alto next?

Once I know two designs behave differently, I’d want to compare each one against both the intended target and a target with one mismatched base. That gives me a more useful question than “Which binds tightest?” Does the chemistry help the candidate stay on its intended target while allowing it to release the mismatch?

Nicoya’s complementary DNA study on Alto Digital SPR puts numbers on the sample and bench time for an oligonucleotide assay. Alto prepared five concentrations from a single stock directly on the cartridge, using 2 µL of sample per interaction. Nicoya reported 48 repeat measurements of the same DNA pair in under five hours, with about 30 minutes of hands-on time for setup and analysis.

Here’s how I’d budget a comparison on Alto. Two candidates, two targets and duplicate runs make eight interactions. At the DNA study’s consumption, that’s 8 µL of each candidate for the measurements, plus material for setup and handling. That makes the mismatch control easier to keep when sample is scarce. I’d first verify that the modified ASO and RNA give a measurable binding and release signal on the chosen surface.

Which candidate deserves the cell experiment?

A study of fluorescently labeled gapmers targeting MALAT1 shows why I’d carry the structural comparison into the cell work. Nilsson and colleagues used a temperature-controlled Chirascan for CD spectra and melting measurements. Duplexes with a single label had spectra close to the unlabeled control. Two candidates with a pair of modified adenines showed small differences between 280 and 340 nm. Those same candidates reduced the target RNA less effectively in a separate cellular assay. If I were choosing a fluorescent label for my next experiment, I’d want one that preserved both the duplex spectrum and the activity of the original gapmer.

For a drug that works like olezarsen, I’d also ask whether the chemistry supports cleavage. A gapmer’s central DNA stretch pairs with RNA to form the substrate recognized by RNase H1. A fully 2′-O-methyl candidate can pair with RNA while lacking that central DNA stretch. For olezarsen itself, researchers measured the intended effect directly. In a study reviewed by the FDA, olezarsen reduced APOC3 RNA by up to 82% in primary human liver cells.

If two candidates melt near 70 °C, I’d spend the next sample on the question that could change my decision. If I’m unsure what formed, I’d compare the full Chirascan spectra with the individual strands. If I’m choosing between designs for their ability to distinguish a single mismatch, I’d use Alto to compare how they release the matched and mismatched targets. And if I’m choosing which gapmer to advance, I want to see the target RNA come down in cells. That gives me a reason to order more of one molecule, even when its melting temperature looks just like the other one’s.


Desmond Gilmour

Email: dgilmour@nicoyalife.com

Phone: +1 519-546-9876

I work at Nicoya Lifesciences. The views expressed here are my own and do not necessarily reflect those of Nicoya. This is a personal publication, not an official company communication.