I compare plate-based SUPR-DSF with capillary nanoDSF for recurring protein stability screens, from automation and consumable costs to the data an AI model needs.

Eight protein variants in six buffers gives you 48 measurements. Run each one twice and you’re at 96. Try two salt concentrations and you’re at 192 measurements before adding a blank or reference. You’re still working with the same eight proteins.

That’s why I’d choose Nicoya’s SUPR-DSF for a lab running stability screens every week. Those 192 measurements occupy half of one standard 384-well plate. A liquid handler can prepare that plate, the instrument can read it directly, and the team can carry the same well map into its analysis. That last part becomes especially valuable when you want a model to learn from the experiment and suggest what to test next.

The plate your liquid handler fills is the plate your instrument reads

You can start with a multichannel pipette. When the workload grows, a liquid handler can dispense into the same type of 384-well qPCR plate. Seal it and load it into SUPR-DSF. The sample your liquid handler dispensed into B7 is still in B7 when you open its unfolding curve.

With individual Prometheus Panta capillaries, each prepared sample goes into a glass capillary and each capillary is positioned on the tray. The Panta user manual specifies up to 48 individual capillaries per load. Our eight-variant example would fill four manual loads before controls.

There’s a concrete example of how easily the plate workflow extends to automation. In a manufacturer study using SUPR-DSF, a Dragonfly liquid handler dispensed lysozyme into plates. After sealing, a PlateCrane moved each plate from a stack to the reader and returned it when the run finished. The setup measured 16 plates in 26 hours. Across 6,096 repeats of the same protein, the apparent melting temperature (Tm) had a standard deviation of 0.14 °C.

That’s the test I’d borrow for a demo. Put your own reference protein across two plates and run them through the setup you plan to use. If a half-degree improvement would change which variant you advance, you’ll know how that compares with the variation in your own experiment.

The consumable savings start well before the plate is full

I budget about US$13 on average for a compatible 384-well qPCR plate and optical seal together. A full plate works out to 3.4 cents per measurement. For the capillary comparison, I used Fisher Scientific’s U.S. listing of $404.25 for 400 Panta-compatible standard capillaries, or about $1.01 per measurement.

Measurements SUPR-DSF plate and seal Plate cost per measurement Individual capillaries used
48 $13.00 27.1¢ $48.51
96 $13.00 13.5¢ $97.02
192 $13.00 6.8¢ $194.04
384 $13.00 3.4¢ $388.08

Even if you measure the original 48 conditions just once, that’s about $36 saved on sample holders at these prices. Run them in duplicate and the difference is about $84 per screen, or $4,200 over 50 screens. Actual savings depend on your supplier pricing.

What I like at the bench is simpler. Once the plate is open, adding reference wells or another replicate for a difficult sample carries the same plate-and-seal cost.

What should an AI model learn from a stability screen?

Ginkgo Bioworks offers a real example. In its peer-reviewed PROPHET-Ab study, the team used SUPR-DSF for the thermal-stability arm of a project spanning 246 antibodies and 10 developability assays. The thermal measurements used 10 µL per well at 0.25 mg/mL, or 2.5 µg of antibody per well. The researchers combined assay results to train a machine-learning model that scored how closely an antibody’s profile resembled those of approved antibodies.

For a formulation team, I’d use the same ability to connect a sample to its measurements, but give the model a more immediate job: choose the next set of buffers worth making.

Consider what happened in a SUPR-DSF screen of infliximab across 96 buffers. All 96 conditions fit in triplicate on one plate. The buffer the team selected raised the antibody’s first unfolding transition by 2.3 °C and its second by 1.3 °C relative to the control. Other buffers pushed the second transition higher. A model trained only to maximize that later peak would have favoured a different formulation.

Here’s how I’d set up the next round. I’d join each well’s protein ID, buffer, pH, salt concentration and replicate number to the raw curves and fitted results that SUPR-Suite exports as CSV. I’d keep both transitions where they appear. Then I’d ask the model to suggest conditions likely to improve the first transition while preserving the second. The liquid handler could prepare those suggestions alongside the original reference, ready to test on the next plate. That gives the team a prediction it can check with fresh data.

When two buffers have similar melting temperatures

Sometimes the better question is what happens when the protein cools. On SUPR-DSF, modulated scanning fluorimetry (MSF) uses heating and cooling cycles to track when the protein’s natural fluorescence stops returning to its starting profile. A capillary platform such as Panta can use dynamic light scattering (DLS) to follow changes in particle size during heating. Those measurements tell you different things about the sample.

In Nicoya’s human IgG experiment, SUPR-DSF detected the onset of incomplete fluorescence recovery at 63.7 °C. A separate DLS experiment on a DynaPro instrument detected aggregation onset at 70.3 °C. For that antibody, the fluorescence picked up a lasting effect of heating several degrees before the sizing experiment flagged particle growth. If two buffers look equally good on melting temperature, recovery gives me another measured reason to favour one for follow-up.

Where I’d put the budget

For a lab building an automated, AI-assisted protein stability workflow, I’d put SUPR-DSF on the bench. The same plate format works for an experiment you pipette today and a stack of experiments you automate later. The consumable cost makes it practical to keep the repeats and controls, and the full fluorescence curves give the analysis team something to revisit when a single melting temperature hides a trade-off.

I’d use the first plate to find promising conditions, the next to test the model’s suggestions against the same references, and fresh aliquots of the finalists to check recovery. That’s where the efficiency pays off. By the time the team commits its next batch of protein, it has measured why one formulation deserves it.