Teaching AI About Disordered Proteins? I’d Start at 50 Milliseconds

If AlphaFold gives you 25 different pictures of two proteins bound together, which one would you trust enough to plan an experiment around?

If AlphaFold gives you 25 different pictures of two proteins bound together, which one would you trust enough to plan an experiment around?

A LinkedIn post about AlphaFold and disordered proteins got me thinking about that question from the lab’s side. I think there’s a specific gap we can fill with FastHDX. We can measure which stretches of a disordered protein change when a partner binds, including changes that are visible only in the first fraction of a second of labelling. Put those measurements in a public databank and the same experiment can help one team judge a structure today and another train a model to predict which regions will respond in the next protein pair.

One team really did have 25 models to choose from

In a study of the progesterone receptor and its partner SRC3, Matthew Mann and colleagues generated 25 AlphaFold 3 models. Both proteins have large disordered regions. Across predictions, one of the things that varied most was where the two proteins sat relative to each other. The researchers used hydrogen–deuterium exchange mass spectrometry (HDX-MS) and a program called HDXer to identify the model that best fit their measurements for visualization. You can download the experimental data from PRIDE under PXD056400.

An intrinsically disordered protein (IDP), or an intrinsically disordered region (IDR) within a larger protein, can sample many shapes. Some regions settle into a fold when they bind. Others stay mobile even with a partner attached. In a benchmark of known complexes, AlphaFold-Multimer produced at least acceptable structures for more than 76% of cases in each dataset. For the group that stayed particularly flexible when bound, only about 3% of predictions reached the high-quality category. That’s a good reason to use the software and an equally good reason to ask what the protein actually did in solution.

What FastHDX can capture before two samples look the same

In HDX-MS, a lab exposes the protein to heavy water. Hydrogens along its backbone exchange with deuterium. After a set time, the lab slows the exchange, cuts the protein into short pieces called peptides, and measures how much deuterium each peptide picked up. Run the protein alone and again with its partner already bound. A peptide that takes up less deuterium in the complex has become more protected. The partner might touch that stretch directly, or binding elsewhere might stabilize it.

The progesterone receptor study’s first labelled sample was at 10 seconds. Why would I want to start earlier? Consider a domain of CREB-binding protein. In an early experiment, exchange was nearly complete across the free domain by ten seconds. When researchers measured the same region on a millisecond timescale, they could distinguish its fast-exchanging ends from its slower centre. Adding its binding partner, ACTR, protected the centre further. A ten-second reading alone could miss what made those regions different.

Nicoya specifies a labelling range of 50 milliseconds to 24 hours for FastHDX. It automates the mixing and quenching upstream of the mass spectrometer. That means I can put the free protein and the complex on the same schedule, early enough to catch fast exchange and long enough to follow the protected stretches. Here, 50 milliseconds is the time the sample spends in heavy water. The partners have already had time to bind.

There’s a disordered protein example from the instrument’s own history. Neeleema Seetaloo and colleagues studied full-length, monomeric α-synuclein on the FastHDX prototype called ms2min. Across the solution conditions they tested, faster exchange around residues 115–135 correlated with a shorter wait for aggregation to begin. The sequence was identical every time. The exchange curves and the buffer tell a model something the sequence alone can’t.

Where the data go, and who already uses them

The developers of HDXRank collected experimental HDX data from PRIDE and MassIVE, trained a model to rank candidate structures of protein complexes, and released their training dataset. For training and evaluation, they chose 30 seconds to 10 minutes because that interval contained the most uptake measurements. That’s where I see an opening for labs with FastHDX. We can contribute paired measurements in the first second, while some of the most flexible peptides are still picking up label.

What we can share Where another team can find it
Raw spectra, peptide uptake tables and experimental conditions Deposit them together in PRIDE or MassIVE. For a real example, a study of engineered protein switches used ms2min from 100 milliseconds to 100 seconds and deposited its HDX data as PXD073666.
Published experimental evidence that a particular sequence region is disordered Submit the evidence to DisProt for curation. Its α-synuclein entry shows how readers can trace a regional annotation back to an experiment.
A set of three-dimensional conformations built or refined using the data Deposit the ensemble in the Protein Ensemble Database and link it to the experimental dataset so researchers can examine both.

What I’d actually give a model developer

Suppose one peptide takes up 3.0 daltons alone and 1.8 with its partner at 250 milliseconds. By ten seconds, both samples reach 5.0. Those numbers are hypothetical. Here’s how I’d use them. Give the model the two sequences, the peptide’s position, the solution conditions and the labelling time. Ask it to predict the change in uptake. The measured answer is −1.2 daltons at 250 milliseconds and zero at ten seconds. A peptide the lab never detected gets marked as missing. That ten-second zero is worth keeping.

For a pilot, I’d measure one known pair at 50 ms, 250 ms, 1 s, 10 s and 1 minute. Two states and three independent repeats make 30 timed measurements. At Nicoya’s stated 8 µL per time point, that’s 240 µL for the timed measurements, before controls and handling losses. The autosampler lets a lab queue additional pairs on that same schedule. I’d publish one row per peptide, state, time and replicate, with the raw file reference, sequences, concentrations, pH, temperature and deuterium fraction, following the HDX-MS reporting recommendations.

Once enough families are represented, I’d hold one entire protein family back from training. Give two models the same measurement budget, let one learn from early and late data and the other from later times alone, then ask each to rank the held-out peptides by how much binding protects them. The useful result for a lab is whether those first few time points change which stretch it would investigate next.

That’s why I’d choose FastHDX to help build this dataset. We can always take another model back to an archived spectrum. We can’t take a ten-second sample back to 250 milliseconds to recover a difference that’s already gone. If we want AI to get better at disordered proteins, I’d start by making those first 50 milliseconds as easy to download as a predicted structure.