Which Antibodies Go on the Next Plate? How Nicoya Fits Into an Automated Lab

Say a lab has more than 180 antibodies and one target. Which of them deserve another experiment? And if the binding screen finishes after everyone’s gone home, does confirming the hits have to wait until the team comes back?

Say a lab has more than 180 antibodies and one target. Which of them deserve another experiment? And if the binding screen finishes after everyone’s gone home, does confirming the hits have to wait until the team comes back?

That’s what I want to work through here, one instrument at a time, with an eye on what each measurement lets the team decide. With Alto SPR, a robot can swap the sensor cartridges and the lab’s scheduler can pull the binding results to queue up a follow-up. A plate handler can load SUPR-DSF with 384-well plates, so the team can compare hits on thermal stability as well as binding.

Once you’re down to a few finalists, the questions get more specific. Does the protein hold its fold as the formulation changes? A pipetting robot can prepare a series of samples for the Chirascan Q100 to measure by circular dichroism (CD). And if you want to know whether two binders protect different regions of the target, the FastHDX autosampler can queue samples for hydrogen–deuterium exchange mass spectrometry (HDX-MS), which lets the team compare deuterium uptake region by region.

Let’s start with the screen itself. In Nicoya’s automated antibody screen, an Opentrons Flex prepared the samples, a Brooks PF400 robot arm loaded four cartridges, and Alto measured binding over 32 hours. Nicoya’s software then called hits from the binding curves, and Figure 2 in the poster shows 12 hits and four intermediate results.

Those four in the middle are my favourite part of the whole experiment. A plain yes-or-no report would treat a borderline signal and a flat curve as the same answer, and they really aren’t. Keep that distinction and suddenly the lab has a much better idea of what to put on the next plate.

How can one binding result change the next run?

Alto uses surface plasmon resonance (SPR) to follow binding as it happens. In this screen, the antibodies went in straight from the liquid the cells were grown in. The Opentrons diluted them and filled the cartridges, and the Brooks arm moved each cartridge into Alto and took it back out when the run was done. Each fresh cartridge brings its own sensors and fluid channels. If you want to see what that looks like, Nicoya posted a video on LinkedIn of Alto running in an automated setup.

There’s a sample-saving bonus on the confirmation run, too. In a separate antibody kinetics experiment, Alto prepared five concentrations right on the cartridge from as little as 2 µL of analyte stock per sample well. So the liquid handler can load a single stock instead of making up a separate well for every dilution. The curves let you compare association and dissociation rates, which is how you’d catch two candidates with similar affinity that don’t stay bound for the same length of time.

The Alto Automation Suite also gives the lab’s scheduling software a way to talk to the instrument. Through its SiLA 2 application programming interface (API), the software can check whether Alto is ready, start a run and pull the results back. That last step is the important one, because it’s where a binding instrument can help close the loop.

Take those 12 hits. A lab could send them on to a second SPR run at several concentrations to measure how quickly each antibody binds and lets go. The four borderline samples could go back for a repeat screen. And if the known binder used as a control fails, the scheduler could hold the whole batch until someone reviews it. To be clear, Nicoya demonstrated the screen and the automated hit calling. The loop only closes when the lab connects those results to a rule that changes what runs next.

For teams running smaller batches, Revo 4 and Revo 8 can be integrated through a software API as well. Revo’s cartridge handles the sample and buffer movement and prepares the serial dilutions, so the liquid handler can get on with other work while Revo collects binding curves.

Who ends up buying the instrument?

A biotech doesn’t need to own an SPR system to get binding data. Ginkgo’s cloud lab is a good example. A customer names a target and a protein known to bind it, and Ginkgo uses Alto to check that the target still binds once it’s attached to the sensor. If it passes, that surface is qualified for later binding experiments. If it fails the quality check, the customer gets one repeat on a fresh cartridge. A startup can buy that answer before it commits a whole set of designs to a screen.

Ginkgo also reported its first autonomous-lab sale to a major pharma company, Novo, for a new R&D site in Waltham, and it runs experiments for customers in its own Nebula cloud lab. To me, that changes who buys the instruments. A dozen small biotechs can create the demand for binding data, and the operator serving them can be the one who picks the SPR system.

What can a model learn from a plate of antibodies?

An antibody can bind its target just fine and still unfold too easily. In a peer-reviewed study of 246 benchmark antibodies, Ginkgo used SUPR-DSF for intrinsic differential scanning fluorimetry, which follows changes in a protein’s own fluorescence as it heats up. Each measurement took 10 µL in a 384-well plate, and because the signal comes from the protein itself, the team could compare thermal unfolding across candidates without adding a reporter dye. Ginkgo’s software tracked each sample from design through measurement, so every antibody’s melting data could be linked back to its sequence.

Then the data got put to work. In a blinded prediction competition, teams used the 246-antibody set for training and predicted properties for 80 more without seeing their measured values. For the temperature of the second unfolding transition, the best model reached a rank correlation of 0.392. So it got some of the order right, from less stable to more stable, but plenty of antibodies ranked differently once they were actually measured. That’s a pretty concrete job for automated measurements in AI discovery. They give a model the examples it learns from, and they also show you where its predictions still miss.

The robotic plate handling has been shown separately. In Protein Stable’s automation study, an SPT Labtech Dragonfly dispensed the same protein into 384-well plates, and a Hudson Robotics PlateCrane loaded and unloaded SUPR-DSF. Across 6,096 measurements in 26 hours, the melting temperature had a standard deviation of 0.14 °C. That’s a tight spread for more than a day of runs.

What if the next experiment needs a closer look at structure?

The NIH Biophysics Core Facility shows how this can work. A pipetting robot can prepare a series of samples with increasing amounts of a chemical that unfolds the protein, and a Chirascan Q100 autosampler feeds them one after another through the same CD measurement cell. Scientists get more points along the unfolding curve without having to make up every concentration by hand. Far-UV CD is also a useful structural check when two formulations have similar melting temperatures, since the team can compare their spectra for signs of a change in secondary structure.

Nicoya has also announced plans for batch processing and an API for Chirascan Analysis Workbench. That API is for the analysis software, and no release date has been announced. Depending on which functions come out, a lab could eventually send a reviewed CD result back to the same sample record that holds its binding and stability data.

Sometimes the next question is where the protein changed. FastHDX automates the timed labeling step in hydrogen–deuterium exchange mass spectrometry, the part where the protein is exposed to heavy water, and it can time those exposures down to 50 milliseconds. It then quenches the exchange and passes the sample into the lab’s liquid chromatography–mass spectrometry (LC–MS) system. Those early time points matter when two regions or conditions take up label differently at first but look alike by the first reading on a seconds scale. Comparing how much label each region takes up can turn up changes that a whole-protein measurement would miss. Nicoya reports integrations with Waters and Thermo Fisher, which gives mass spec cores a way to add those early measurements to the setup they already have.

The FastHDX autosampler keeps all of that going between samples, feeding whatever’s next in the queue into FastHDX, which controls the labeling and the quench. Nicoya specifies up to six samples and 24 hours unattended on the base system, and up to seven days with the autosampler, and the launch announcement lists capacity for up to 192 samples with robotic expansion. For a core comparing several candidates, the practical upside is being able to schedule multiple conditions and replicates without sending someone back to reload every sample. How much of that queue fits into a run still comes down to the labeling time points and the LC–MS method.

What actually closed the loop at the bioreactor?

November’s BALANCE demonstration at CPI shows how different pieces of automation can work together. Labman’s robot collected and prepared the bioreactor samples, and Alto ran calibration standards and measured antibody titer (the concentration of antibody in the culture liquid) while the cells were still producing it.

Basetwo’s account of the control system spells out who used which measurement. Their controller adjusted feeding based on process readings and glucose measurements. The team used Alto’s independent titer measurements to compare antibody production in the controlled cultures and the manually fed ones. So the controller decided when to feed the cells, and Alto’s titer numbers told the scientists whether that strategy actually got them more of the product they cared about.

If you’re thinking about this for your own lab, I’d start with one decision worth automating. For an antibody team, that might just be which samples get a second run tomorrow. Alto sends back the binding results, the scientists decide what counts as a hit and what counts as borderline, and the scheduler holds wells for both. The startup that ordered the screen could wake up to confirmation curves for antibodies it didn’t even know were hits the day before.

That’s the piece I see Nicoya bringing to lab automation. A binding curve is a lot more useful when it can change what the robot does next, instead of sitting in a folder until somebody gets in the next morning.